DESCRIPTION The FT63 contains a reservoir of cooled fluid, which is pumped through the external process to be cooled (eg heat exchanger system). The cooling fluid can be water or a mixture of glycol and water depending on the output temperature required.This fluid is cooled by the integral refrigerationsystem.A high-pressure pump is used to pump the fluid through the process. A bypass valve facility enables the fluid to be recirculated independently of the process conditions. Compressor Reciprocating hermetically sealed compressor with a refrigerant cooled motor. Evaporator Packaged coil type, made of copper tubes and aluminium fins. Condenser Single air-cooled condenser manufactured from aluminium fins mechanically bonded to refrigeration-grade copper tubes. The condenser fan is of a low-noise axial type. Fan blades are fully enclosed by a safety grill.
TECHNICAL SPECIFICATIONS COOLING CAPACITY The cooling capacity of a chiller is dependent on its operating conditions, particularly the liquid temperature and concentration. The FT63 has a typical cooling capacity of 2kW with an outlet temperature of 0°C, using a 20% glycol solution (typical FT174X application). For other applications please consult Refrigerant: R407C Freon Max ambient temp: 32°C PROCESS PUMP Head: 6 bar max Flow rate: 4.8 m³/hr at 3.7 bar Reservoir capacity: 25 litres